SECO-LARM USA SK-1123-SQ Door User Manual


 
Digital Access Keypad Manual
SECO-LARM U.S.A., Inc.
Digital Access Keypad Manual
12-24V AC/DC universal power -- No programming or jumpers needed.
Mantrap -- Each keypad can be used as a stand-alone keypad. However, the mantrap
feature uses two keypads to protect an area with two doors by ensuring that only one
door is open at a time. With the mantrap interlock functions, when a user keys in the
code to open one door, a signal is sent to disable the second keypad, thereby
preventing access through the second door until the first door is closed.
Relay output #1 inhibit control -- Relay output #1 is typically used for a door strike.
If the keypad is set to the "inhibited" mode, relay output #1 will not operate. This
increases the security of the protected premises during the time it is not expected to
be occupied, such as during evening or weekend hours. An authorized user can
enable or disable the inhibit control by using the code for relay output #2 at any time,
depending on how installed.
Door forced open warning -- When used with an optional magnetic contact, the
keypad beeps continuously if the door to the protected premises is forced open
without using a valid user code. The warning can be stopped only by closing the
protected door.
Door propped open warning -- When used with an optional magnetic contact, the
keypad beeps continuously if the door is propped open after the allowed open time.
The allowable open time is programmable. The warning stops when the door is re-
closed.
Auto or manual code entry checking:
Auto code entry checking mode -- When all the user codes have the same number
of digits, the keypad will activate automatically when the code is entered. There is
no need to press the "#" key. This is convenient for the users.
Manual code entry checking mode -- The user codes can vary in number of digits,
and the user must press the "#" key when finished entering the code. This
increases security.
Keypad active output -- This NPN transistor open collector ground (-) output
activates for 10 seconds when any key on the keypad is pressed. This can be used to
trigger a video recorder or turn on a light, or to signal a guard that someone is
entering the protected premises.
Door auto relock -- The keypad will relock an open door either when the relock time
expires or immediately after the door is closed, depending on which occurs first. This
prevents unwanted "tailgate" entries, which can happen if an unauthorized person
tries to follow an authorized person through the door.
Duress output -- This NPN transistor open collector ground (-) output can be used to
trigger a silent alarm if an authorized user is forced under duress to use the keypad.
The duress output is activated by adding 2 to the first digit of user code 1. In this
case, the protected door opens as it would normally, but a signal is quietly sent to a
remote device to call for help without alerting the unauthorized person.
Backlit keypad --
The keypad is backlit to increase nighttime visibility. For
convenience,
the lighting intensity will increase for 10 seconds after any key is
pressed.
UNIQUE FEATURES
(DEFAULT: )
X X X X
*
0 0 0 0
*
#8 9 0 1
#
#
4 0
4 1
#
#
5 0
#
#
7 0
7 1
7 2
7 6
#
#
8 0
1
0
#
#
8 1
1
0
Confirm
#
#
8 2
1
0
#
#
8 3
1
0
#
#
9
#
#
0 0 0 0
*
#
#
5 1
0 0
Enter Master code
*Key in the Master Code.
Note: For first-time use, Master code is
Confirm
Function
Enter into programming mode
Enter Programming Mode
Configure Relay Outputs
Option Output time
1 to 999
Confirm
Function
Relay #1, momentary mode, from 1 to 999 seconds
Relay #1, shunt mode (ON/OFF)
INSTALLER PROGRAMMING
These functions should only be used by professional installers, as incorrect entries can disable the entire keypad function.
Relay #2, momentary mode, from 1 to 999 seconds
Wrong Code Lockout
Option
# of tries
5 to 10
Confirm
Function
After 10 successive wrong codes, 30-second lockout
After 10 successive wrong codes, Duress activated
After 5 to 10 wrong codes, 15-min. lockout - Can reset with Master Code
None of the above
Door Forced-Open Alarm
Option Code entry
Confirm
Function
Door forced-open alarm is enabled
Door forced-open alarm is disabled
Output Activation Announcer
Option Code entry
Confirm
Function
1-sec. beep notifies the user to open the door when the output relay is activated with the
user code or egress button. Use with a locking device which gives no sound when it
activates, such as a magnetic lock.
The beep is disabled, replaced by 2 short beeps for valid user codes.
User Code Entry Mode
Function
Auto Entry Mode is selected. The key that follows the user code is NOT required in
code entry. The User Codes MUST be set to the same digit length as the Master Code,
from 4-8 digits.
Manual Entry Mode is selected. The key that follows the user code is required in
code entry. The User Codes can be 4-8 digits, but not necessarily all of the same length.
Keypress Beeps
Option Code entry
Confirm
Function
Keypad beeps when a key is pressed.
Silent operation -- keypad does not beep when a key is pressed.
Door Propped Open Alarm Timer
Option Code entry
Confirm
Function
No door propped open alarm
Allowable time from 1 to 999 seconds that the door can be left open before the door
propped open alarm starts
Exit Programming Mode
Function
Exits programming mode, returns keypad to normal operations
(DEFAULT: Momentary, 1-sec. output for both outputs)
(DEFAULT: 10 tries / 30 seconds)
(DEFAULT: Disabled)
(DEFAULT: On)
{
{
(DEFAULT: Manual)
(DEFAULT: On)
(DEFAULT: Off)
Data Refresh
Option Confirm Function
Clears all previously stored data.
1 to 999
{
{
Option Code entry
{
0
1 to 999
Confirm
Relay #2, shunt mode (ON/OFF)
Page 14 Page 3