I
AVOID SERVICE CHECKLIST
,
Before calling for service, review this list. It may save you both time and expense, This list includes
common problems that are not the result of defective workmanship or materials in this appliance.
OCCURRENCE
Air conditioner will not
operate.
POSSIBLE CAUSE
Wall plug disconnected.
SOLUTION
Push plug firmly into wall outlet.
House fuse blown or circuit
breaker tripped°
Replace fuse with time delay
type or reset circuit breaker.
Thermostat set too warm for
cooling or too cool for heating.
Adjust thermostat to higher
number for cooling, lower
number for heating.
Air from unit does not feel
cold enough on Cool setting
Selector switch in FAN
position.
Thermostat set too warm
(lower numberL
Turn switch clockwise to
COOL position.
Turn thermostat clockwise to
colder setting (higher numberL
Thermostat temperature
below 70°F (20°CL
Cooling may not occur until
temperature at thermostat
rises above 70°F (20°CL
"temperature sensing tube
touching cold coil, located
behind air filter (some rnodels
onlyL
Straighten tube so it does not
touch coil,
Air conditioner cooling,
but room is too warm-
ice forming on cooling
coil behind decorative
front.
Outdoor temperature below
70OF (20oc).
TO defrost the coil,, set
thermostat to a warmer
position_
Dirty air filter-air restricted, clean filter'.
Thermostat set too cold for
_night-time _cooling.
To defrost the coil, set
thermostat to a normal
position. " _
Air conditioner cooling but
room too warm-NO ice
forming on cooting coil
behind decorative front,
Dirty air filter-air restricted.
Clean air filter. Refer to "Care
and Cleaning" section.
Thermostat set too warm
(lower number).
Turn thermostat clockwise to
colder temperature,
Selector switch set on LOW
COOL.
Turn switch to HIGH COOL
position for maximum
cooling.
Vent control (some models)
set at OPEN position.
Turn control to CLOSED
position for maximum
cooling
Air directional louvers posi-
tioned Improperly.
Position louvers for better air
distribution.
8