Sears 758.14808 Humidifier User Manual


 
HOUSING .FILTER
INDICATOR OVERRLL
HOLE
FigureI
FILTER
HOUSSNG
...... i i ,,ll,ln,i
oe,c ptzon ......
Gallon Output
Tank Capacity
Sq: R. Coverage
Fan Speeds
Filters
Fill Light
Water Level Indicator
m I ,, ]1 J
758.148080
8
5 gallons
2000
Variable
1
Yes
Yes
Auto Humidstat
Auto Shut Off
Dry OUt
U_L_LTst_J
AHAM Certified
Volts
Hertz
Amps
Watts
Yes
Yes
Manual
?es
Yes
120 A.C.
6O
2.0
140
Humidifier Operations
"four new Sears humidifier is designed to
satisfy home humidity requirements
through the principle of evaporation of
water into the air.
After water is added to the tank, the filters
begin to soakup the water and become
totally saturated in approximately 30 min-
utes; Air is drawn in from the top of the
humidifier by means of a circulation fan
and drawn through the filter. As air passes
through the filter, moisture is absorbed by
the air and then released through the top
of humidifier. (See Figure 2) This moist air
is released in the form of vapor. No water
droplets will enter the home. All evapora-
tion into the air takes, place in the humidifi-
er, which means that the residue left by
evaporating ,_ater is not passed into the
home, but remains in the filter.
- CAUTION .............
Use on!y 32-14900 EPA Registered
Bacteri_stat available from SEARS
Retail store. Use of other water treat-
ment products may damage the filter
or .nay pose health hazards.
Under no circumstances should you
use water treatment products de-
signed for Roto belt or Ultrasonic
humidifiers.
3
CAUTION ....
Keep your humidifier clean. While
humidifiers do not cause colds, some
studies suggest that dirty humidifiers
can cause cold-like symptoms in
some people. To avoid this, clean
your humidifier weekly with
Humidifier Cleaner 32-7283 and use
Bacteriostat 32-14900. These are
available at your local Sears store.
MOTOR
FILTER
FLOAT
WATER
#UMIOIREOAIR
DRY
ROOM
t" !
AIR
,/
il
Figure 2