INSTALLATION STEP 9
Electrical Requirements
To avoid installation difficulties, do not run the
opener at this time.
To reduce the risk of electric shock, your garage door
opener has a grounding type plug with a third
grounding pin. This plug will only fit into a grounding
type outlet. If the plug doesn't fit into the outlet you
have, contact a qualified electrician to install the
proper outlet.
If permanent wiring is required by your local
code, refer to the following procedure.
To make a permanent connection through the 7/8"
hole in the top of the motor unit:
Remove the motor unit cover screws and set the
cover aside,
Remove the attached 3-prong cord.
Connect the black (line) wire to the screw on the
brass terminal; the white (neutral) wire to the
screw on the silver terminal; and the ground wire
to the green ground screw. The opener must be
grounded.
Reinstallthe cover.
TopreventpossibleSERIOUSINJURYor DEATHfrom
electrocutionor fire:
Besure power is notconnectedtothe opener,and
disconnectpowerto circuit BEFOREremovingcoverto
establishpermanentwiring connection.
Garagedoor installationand wiring MUSTbe in
compliancewith all localelectricaland buildingcodes.
NEVERuseanextensioncord, 2-wireadapter,or
changeplug in any wayto makeit fit outlet. Besure
the openeris grounded.
PERMANENT WIRING
CONNECTION
Ground Tab
Green
Ground Screw
White /
2O