Sears 139.53971SRT Garage Door Opener User Manual


 
ONE-PIECE DOOR WITHOUT TRACK
1. Close the door and mark the insidevertical
centerline of your garage door. Extend the line
onto the header wall above door, as shown.
If headroom clearance is minimal, you can install
the header bracket on the ceiling. See page 14.
If you need to install the header bracket on a 2x4
(on wall or ceiling), use lag screws (not provided)
to securely fasten the 2x4 to structural supports
as shown.
2. Open your door to the highest point of travel as
shown. Measure the distance from the top of the
door to the floor. Subtract the actual height of the
door. Add 8" to the remainder. (See Example).
3. Close the door and draw an intersecting horizontal
line on the header wall at the determined height.
NOTE: If the total number of inches exceeds the
height available in your garage, use the maximum
height possible, or refer to page 14 for ceiling
installation.
Header Wall
Unfinished
Ceiling
Vedical
Centerline
CEILING MOUNT
FOR
HEADER BRACKET
EXAMPLE
Distance from top of door
(at highest pointof travel) to floor ...................... 92"
Actual height of door.......................................... -88"
Remainder .......................................................... 4"
Add ..................................................................... +8"
Bracket height on header wall............................ =12"
(Measure UP from top of CLOSED door.)
Proceed toStep _ page 14.
Header Wall
/ Highest Point
of Travel
"7
Q
One-piece door without track:
jamb hardware
Floor
One-piece door without track:
pivot hardware