Sanyo SAP-CMRV1426EH-F Air Conditioner User Manual


 
Outdoor Unit SAP-CMRV1936EH
Indoor Unit SAP-KMRV96EH
× 3
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
1. The values shown in perfromance section and electrical rating section above are based on the following unit combination.
For other combination unit, please refer to the "Unit Combination Table" in this manual.
Indoor Unit: SAP-KMRV96EH 3units Outdoor Unit: SAP-CMRV1936EH 1unit
2. Rating conditions are: Cooling: Indoor air temp. 27°C D.B. / 19°C W.B.
Outdoor air temp. 35°C D.B. / 24°C W.B.
Heating: Indoor air temp. 20°C D.B.
Outdoor air temp. 7°C D.B. / 6°C W.B.
Operation Sound Hi dB-A
Refrigerant Control
( 3.4 to 8.4 )
( 11,600 to 28,700 )
6.88
1,550
7.70
1,735
5.6
19,100
7.3
24,900
( 2.9 to 6.8 )
( 9,900 to 23,200 )
Shipping Volume
Cooling Heating
2,500
Cooling Heating
Net
Shipping
Weight
Height
× Width × Depth
kg
kg
m
3
mm
230V
2,500
198 to 264
Dimensions & Weight (Outdoor Unit)
Refrigerant Tubing Connections
Unit Dimensions
Electrical Rating
Air Circulation (High)
WPower Input
V
A
Available Voltage Range
Running Amperes
Narrow tube
Wide tube
Refrigerant mm (in.)
Tube Diameter mm (in.)
65.0
69.0
0.38
740
× 900 × 320
6.35 (1/4")
× 3
9.52 (3/8")
× 3
mMax. allowable tubing length per unit
Flare Type
25
Electric Expansion Valve
Compressor
Refrigerant / Amount charged at shipment kg
DC Twin Rotary (Inverter)
R410A / 2.8
Controls
Fan Speeds
Microprocessor
Auto (Hi, Me, Lo)
Features (Outdoor Unit)
C.O.P.
Compressor Locked Rotor Amperes
W/W
kW
Performance
- 4.21
46 47
%Power Factor 98 98
A 14.5
Type
Voltage Rating
BTU/h
Capacity
m
3
/h
3-Room Multi Outdoor Unit
E.E.R. W/W 3.61 -
Number of Connectable Indoor Units 3
Number of Operatable Indoor Units 3
Max. Capacity of Operating Indoor UnitskW 10.5
Power Source 220 to 240V Single-Phase 50Hz
Height × Width × Depth mm
Package Dimensions
868 × 1,050 × 423
9