Sanyo SAP-CMRV1426EH-F Air Conditioner User Manual


 
Table 1
Room Room Room Room Room Room
ABC
Capacity ( Min. - Max. )
ABC
Capacity ( Min. - Max. )
2.2 = 2.2 2.20 2.2 ( 1.4 - 2.6 ) 2.50 2.5 ( 1.8 - 4.3 )
2.65 = 2.65 2.65 2.65 ( 1.4 - 3.2 ) 3.60 3.6 ( 1.8 - 4.7 )
3.5 = 3.5 3.50 3.5 ( 1.5 - 3.6 ) 4.20 4.2 ( 1.9 - 5.1 )
5.15 = 5.15 5.15 5.15 ( 1.6 - 5.8 ) 6.00 6.0 ( 2.0 - 7.8 )
2.2
+
2.2 = 4.4 2.20 2.20 4.4 ( 2.0 - 5.1 ) 2.50 2.50 5.0 ( 2.0 - 6.4 )
2.2
+
2.65 = 4.85 2.20 2.65 4.85 ( 2.0 - 5.8 ) 2.50 3.60 6.1 ( 2.1 - 7.5 )
2.2
+
3.5 = 5.7 1.97 3.13 5.1 ( 2.0 - 6.7 ) 2.35 3.95 6.3 ( 2.1 - 8.3 )
2.2
+
5.15 = 7.35 1.65 3.85 5.5 ( 2.1 - 6.8 ) 2.03 4.87 6.9 ( 2.4 - 8.4 )
2.65
+
2.65 = 5.3 2.50 2.50 5.0 ( 2.0 - 6.3 ) 3.23 3.23 6.45 ( 2.3 - 8.4 )
2.65
+
3.5 = 6.15 2.24 2.96 5.2 ( 2.0 - 6.8 ) 3.07 3.58 6.65 ( 2.3 - 8.4 )
2.65
+
5.15 = 7.8 1.90 3.70 5.6 ( 2.1 - 6.8 ) 2.74 4.56 7.3 ( 2.4 - 8.4 )
3.5
+
3.5 = 7 2.70 2.70 5.4 ( 2.0 - 6.8 ) 3.45 3.45 6.9 ( 2.3 - 8.4 )
3.5
+
5.15 = 8.65 2.27 3.33 5.6 ( 2.1 - 6.8 ) 3.01 4.29 7.3 ( 2.4 - 8.4 )
2.2
+
2.2
+
2.2 = 6.6 1.77 1.77 1.77 5.3 ( 2.5 - 6.8 ) 2.18 2.18 2.18 6.55 ( 2.7 - 8.4 )
2.2
+
2.2
+
2.65 = 7.05 1.69 1.69 2.03 5.4 ( 2.9 - 6.8 ) 2.02 2.02 2.91 6.95 ( 3.0 - 8.4 )
2.2
+
2.2
+
3.5 = 7.9 1.56 1.56 2.48 5.6 ( 2.9 - 6.8 ) 1.94 1.94 3.26 7.15 ( 3.2 - 8.4 )
2.2
+
2.2
+
5.15 = 9.55 1.29 1.29 3.02 5.6 ( 2.9 - 6.8 ) 1.66 1.66 3.98 7.3 ( 3.4 - 8.4 )
2.2
+
2.65
+
2.65 = 7.5 1.63 1.96 1.96 5.55 ( 2.9 - 6.8 ) 1.88 2.71 2.71 7.3 ( 3.4 - 8.4 )
2.2
+
2.65
+
3.5 = 8.35 1.48 1.78 2.35 5.6 ( 2.9 - 6.8 ) 1.77 2.55 2.98 7.3 ( 3.4 - 8.4 )
2.2
+
2.65
+
5.15 = 10 1.23 1.48 2.88 5.6 ( 2.9 - 6.8 ) 1.51 2.17 3.62 7.3 ( 3.4 - 8.4 )
2.2
+
3.5
+
3.5 = 9.2 1.34 2.13 2.13 5.6 ( 2.9 - 6.8 ) 1.67 2.81 2.81 7.3 ( 3.4 - 8.4 )
2.65
+
2.65
+
2.65 = 7.95 1.87 1.87 1.87 5.6 ( 2.9 - 6.8 ) 2.43 2.43 2.43 7.3 ( 3.4 - 8.4 )
2.65
+
2.65
+
3.5 = 8.8 1.69 1.69 2.23 5.6 ( 2.9 - 6.8 ) 2.31 2.31 2.69 7.3 ( 3.4 - 8.4 )
2.65
+
3.5
+
3.5 = 9.65 1.54 2.03 2.03 5.6 ( 2.9 - 6.8 ) 2.19 2.56 2.56 7.3 ( 3.4 - 8.4 )
3.5
+
3.5
+
3.5 = 10.5 1.87 1.87 1.87 5.6 ( 2.9 - 6.8 ) 2.43 2.43 2.43 7.3 ( 3.4 - 8.4 )
Table 2
Room Room Room Room Room Room
ABC
Capacity ( Min. - Max. )
ABC
Capacity ( Min. - Max. )
2.65 = 2.65 2.65 2.65 ( 1.4 - 3.2 ) 3.60 3.6 ( 1.8 - 4.7 )
3.5 = 3.5 3.50 3.5 ( 1.5 - 3.6 ) 4.20 4.2 ( 1.9 - 5.1 )
= 5.3 2.35 2.35 4.7 ( 2.0 - 6.0 ) 3.20 3.20 6.4 ( 2.3 - 8.3 )
= 7 2.53 2.53 5.05 ( 2.0 - 6.4 ) 3.45 3.45 6.9 ( 2.3 - 8.3 )
= 7.95 1.77 1.77 1.77 5.3 ( 2.9 - 6.4 ) 2.40 2.40 2.40 7.2 ( 3.4 - 8.3 )
2.65
+
3.5 = 6.15 2.11 2.79 4.9 ( 2.0 - 6.4 ) 3.02 3.53 6.55 ( 2.3 - 8.3 )
2.65
+
2.65
+
3.5 = 8.8 1.60 1.60 2.11 5.3 ( 2.9 - 6.4 ) 2.27 2.27 2.65 7.2 ( 3.4 - 8.3 )
Single-room
Operation
2-room
Operation
3-room
Operation
Total Performance
COOLING
2-room
Operation
Indoor Unit Combination
Indoor Unit Capacity (kW)
COOLING HEATING
Total Performance Total Performance
< Combinations of operatable indoor units >
Single-room
Operation
SAP-CMRV1934EH
(Rated cooling capacity: 5.6 kW)
3-room
Operation
Indoor Unit Capacity (kW)
Indoor Unit Combination
HEATING
Total Performance
2.2: SAP-KMRV74EH
2.65: SAP-KMRV94EH
3.5: SAP-KMRV124EH
5.15: SAP-KRV184EH
2.65: SAP-KRV96EHDS
SAP-CMRV1936EH
NOTE
2.2: SAP-KMRV74/76EH
2.65: SAP-KMRV94/96EH
3.5: SAP-KMRV124/126EH
5.15: SAP-KRV184/186EH
NOTE
2.65: SAP-KRV96EHDS
3.5: SAP-KRV126EHDS
2.65
+
2.65
3.5
+
3.5
2.65
+
2.65
+
2.65
= 9.65 1.46 1.92 1.92 5.3 ( 2.9 - 6.4 ) 2.16 2.52 2.52 7.2 ( 3.4 - 8.3 )2.65
+
3.5
+
3.5
= 10.5 1.77 1.77 1.77 5.3 ( 2.9 - 9.4 ) 2.40 2.40 2.40 7.2 ( 3.4 - 8.3 )3.5
+
3.5
+
3.5
When one or more SAP-KRVxxEHDS indoor units are operated concurrently with one or more SAP-KMRVxxEH
indoor units, the performance specifications of the SAP-KRVxxEHDS models will decrease by 5% from those listed in
the Table 2.
The table lists the wall-mounted type of indoor units as representative models.
For details on the connection of indoor units other than the wall-mounted type, refer to the catalog.
CombinationTable-1936EH.fm Page 3 Friday, September 26, 2008 10:11 AM