Sanyo KS1251 Air Conditioner User Manual


 
11
2-3. Other Component Specifications
2-3-1. Indoor Unit
(1) Indoor unit KS0951
Transformer ATR-T4
Rating Primary AC 115V, 60Hz
Secondary 19V, 0.5A
Thermistor (Coil sensor) DTN-TKS131B
Resistance k 32°F (0°C) 15 ± 2%
Thermistor (Room sensor) DTN-TKS134B
Resistance k 77°F (25°C) 5 ± 3%
Thermistor (Coil sensor) DTN-TKS131B
Resistance k 32°F (0°C) 15 ± 2%
Thermistor (Room sensor) DTN-TKS134B
Resistance k 77°F (25°C) 5 ± 3%
Thermistor (Coil sensor) DTN-TKS131B
Resistance k 32°F (0°C) 15 ± 2%
Thermistor (Room sensor) DTN-TKS142B
Resistance k 77°F (25°C) 5 ± 3%
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
(2) Indoor unit KS1251
Transformer ATR-T4
Rating Primary AC 115V, 60Hz
Secondary 19V, 0.5A
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
(3) Indoor unit KS1852
Transformer ATR-T5
Rating Primary AC 230V, 60Hz
Secondary 19V, 0.5A
DATA SUBJECT TO CHANGE WITHOUT NOTICE.