Sanyo KS1251 Air Conditioner User Manual


 
10
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
(3) Outdoor unit C1852 / CL1852
Control PCB
Part No. — / POW-CL125
Controls
Control Circuit Fuse AC 250V – 5A
Compressor
Type Rotary (Hermetic)
Compressor model C-R132H6D
Nominal output W 1,300
Compressor oil … Amount cc SUNISO 4GSD-T … 500
Coil resistance (ambient temp. 68°F (20°C)) C – R: 1.442
C – S: 2.567
Safety devices Type External (OLR)
Overload relay MRA99117-9200
Run capacitor µF 35
VAC 400
Crank case heater — / 230V, 20W
Heat Exchanger Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch inch (mm) 1/16 (1.6)
Face area ft
2
(m
2
) 4.0 (0.372)
External Finish Acrylic baked-on enamel finish
Fan & Fan Motor C1852 CL1852
Type Propeller
Q’ty … Dia. and length inch. (mm) 1 … 16-17/32 (ø 420) 1 … 16-17/32 (ø 420)
Fan motor model … Q’ty KFG6-51E6P … 1 KFG6T-51B6P … 1
No. of poles … rpm (230V, High) 6 … 830 6 … 830
Nominal output W 50 50
Coil resistance (ambient temp. 68°F (20°C)) WHT BRN: 102 WHT – BRN: 102
PNK WHT: 199 PNK WHT: 199
Run capacitor µF 2 2
VAC 440 440
000-215 SM (1-56) 7/5/00 2:49 PM Page 10