Sanyo CL1251 Air Conditioner User Manual


 
5
2-2. Major Component Specifications
2-2-1. Indoor Unit
(1) Indoor unit KS0951
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Control PCB
Part No. POW-KS095A, POW-KS095B
Controls Microprocessor
Control circuit fuse AC 115V – 3A
Flap Motor
Type Stepping motor
Model MP24GA1
Rating DC12V
Coil resistance (ambient temp. 77°F (25°C)) WHT – BLU (respectively 4 wires): 380 ± 7%
Heat Exchanger Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch inch (mm) 1/16 (1.4)
Face area ft
2
(m
2
) 1.40 (0.130)
Fan & Fan Motor
Type Cross-flow
Q’ty … Dia. and length inch (mm) 1 … ø 95 / L617 (ø 3-3/4 / L24-9/32)
Fan motor model … Q’ty KFV4-21H1PA … 1P
Nominal output W 20
Coil resistance (ambient temp. 68°F (20°C)) BLU BRN: 100.9
BLU PNK: 127.5
Run capacitor µF 3.5
VAC 220
Remote Control Unit RCS-1S2U
000-215 SM (1-56) 7/5/00 2:49 PM Page 5