Sanyo 85464369098000 Air Conditioner User Manual


 
36
XM
3-11. Installing the Drain Piping
(1) Prepare standard hard PVC pipe (O.D. 1-1/32") for
the drain and use the supplied hose band to prevent
water leaks. (Fig. 3-33)
The PVC pipe must be purchased separately.
The transparent drain part on the unit allows you to
check drainage.
(2) Installing the drain hose
To install the drain hose, first place 1 of the 2 hose bands
over the unit drain port and the other hose band over the
hard PVC pipe (not supplied). Then connect both ends of
the supplied drain hose. (Fig. 3-33)
On the unit drain side, grasp the hose band with pliers and
insert the drain hose all the way to the base.
If other commercially available hose bands are used, the
drain hose may become pinched or wrinkled and there is
danger of water leakage. Therefore be sure to use the sup-
plied hose bands. When sliding the hose bands, be careful
to avoid scratching the drain hose.
Do not use adhesive when connecting the supplied drain
hose to the drain port (either on the main unit or the PVC
pipe).
Reasons: 1. It may cause water to leak from the connec-
tion. Since the connection is slippery just
after the adhesive has been applied, the pipe
easily slips off.
2. The pipe cannot be removed when mainte-
nance is needed.
Wrap the hose with the supplied drain hose insulation and
use the 4 twist ties so that the hose is insulated with no
gaps.
Do not bend the supplied drain hose 90° or more. The hose
may slip off.
NOTE
Make sure the drain pipe has a downward gradient (1/100 or
more) and that there are no water traps.
CAUTION
In cases where it is necessary to raise the height of the
drain piping, the drain piping can be raised to a maxi-
mum height of 2.78 ft. above the bottom surface of the
ceiling. Under no conditions attempt to raise it higher
than 2.78 ft. above the bottom surface of the ceiling.
Doing so will result in water leakage. (Fig. 3-34)
Do not use natural drainage.
Do not install the pipe with an upward gradient from
the connection port. This will cause the drain water to
flow backward and leak when the unit is not operating.
(Fig. 3-35)
Do not apply force to the piping on the unit side when
connecting the drain pipe. The pipe should not be
allowed to hang unsupported from its connection to
the unit. Fasten the pipe to a wall, frame, or other sup-
port as close to the unit as possible. (Fig. 3-36)
Provide insulation for any pipes that are run indoors.
CAUTION
Attach so that the hose band
fastener is on the side of the
drain port.
Attach the hose bands so that
each is approximately 13/64"
to 63/64" from the end of the
supplied drain hose.
140
25 25
5
5
Drain port
Twist tie
(4 ties, supplied)
Unit
Drain hose
insulation
(supplied)
Hard PVC pipe
(equivalent to
O.D. 1-1/32")
(Field supply)
Position to
fasten hose
bands
Drain hose
(supplied)
Hose band
(2 bands, supplied)
1 ft. or less
2.78 ft. or less
* Length of supplied drain hose = 5-33/64"
Uphill slope
Support
bracket
CAUTION
Do not install an air bleeder as
this may cause water to spray
from the drain pipe outlet.
Air bleeder prohibited
13/64"
63/64"
5-33/64"
63/64"
13/64"
Fig. 3-34
Fig. 3-35
Fig. 3-36
Fig. 3-33