Sanitaire 800 Vacuum Cleaner User Manual


 
7
A B C D
F
E
D
When properly assembled, the brush roll should rotate freely
between the two end caps. Check the condition of the belt;
change if necessary. Replace the brush roll, belt, and bottom
plate (see How To Replace A Worn Belt).
Ask for GENUINE EUREKA replacement brush strip.
12 inch No. 52282; 16 inch No. 52246-1
TO RE-ASSEMBLE
1. Slide in new brush strip of same length (rounded end
first). Fit track on either side of brush strip into brush roll
slot (F).
Replace second brush strip from opposite end of brush
roll.
2. Replace shaft (E).
3. Align indentation on bearing retainer with brush strip on
both ends of brush roll (D).
(replace shaft washer on sleeve bearing assembly)
4. Position end cap with flat sides of center hole over flat sides
of threaded shaft (C).
5. Tighten locknut (B).
6. Align holes and secure rubber end cap cover flat side
against end cap (A).
1. Remove rubber end cap cover from one end (A).
2. Unscrew locknut (B).
3. Remove end cap (sleeve bearing brush roll assembly
includes a shaft washer, not pictured) (C).
4. Remove bearing retainer (D).
5. Push shaft through opposite end (E).
6. Pull out worn brush strip with pliers (F).
How To Replace Worn Brush Strips
(anodized aluminum spiral)
New brush strip inserts are supplied in sets of two, one long
and one short. To replace, remove bottom plate and belt (see
How To Change Belt). Then, grasp center of brush roll and
lift to remove.
1. Remove rubber end cap cover from one end (A).
2. Unscrew locknut (B).
3. Remove end cap (C).
4. Press down on the brush strip and push out. Slide in new
brush strip of same length, clip first, until clip locks into
place (D). Replace second strip from opposite end. (double
bristle brush roll requires two sets of brush strips.)
TO RE-ASSEMBLE
1. Position end cap so flat side of center hole is over flat side
of threaded shaft (C).
2. Tighten locknut (B).
3. Align holes and secure rubber end cap cover (flat side
against end cap) (A).
NOTE: Some models have two rows of bristles.
When properly assembled, the brush roll should rotate freely
between the two end caps. Check the condition of the belt;
change if necessary. Replace the brush roll, belt, and bottom
plate (see How To Replace A Worn Belt).
Ask for Genuine Eureka replacement brush strip.
12 inch–No. 52140; 16 inch–No. 52264
Order two sets for double bristle brush rolls.
How To Replace Worn Brush Strips
(chromed steel brushroll)
New brush strips are supplied in sets of two, one long and
one short. To replace, remove bottom plate and belt (see
How To Change Belt). Then, grasp center of brush roll and
lift to remove.
1
2
3
Headlight Bulb (Standard on most models)
CAUTION: Turn off the switch and unplug the
electrical cord before replacing headlight
bulb.
Headlight style varies by model. Locate the notches that
release the tabs at either (1) top, (2) side, or (3) bottom of the
lens, as illustrated. Place a screwdriver into one notch; twist or
pry the screwdriver to release the lens. Repeat for the second
notch on the opposite side.
Rotate the bulb socket forward. Push bulb in and turn to
remove. Secure new bulb into socket and rotate bulb socket
backward.
Replace the lens tabs into the top or the bottom of the hood
opening. Rotate lens to position and press down at each notch
until the lens locks into position.
NOTE: Use 25 watt replacement bulb, only.
Ask for GENUINE EUREKA replacement bulb, 40009A.
CLIP
A B C D