Samsung NH300WHXEA Heat Pump User Manual


 
32_ Operating advanced function
Operating advanced function
FIELD SETTING MODE
Field Setting Value(FSV) Table
• Code 40✴✴ : User’s options for heating devices including internal backup heater and external boiler
401
: Space/DHW heating priority and control variables
402
: Backup/Booster heater priority and control variables
403
: Additional backup boiler operating variables
• Code 50✴✴ : User’s options for extra functions
501
: New target temperatures of each mode by “Outgoing” hot key of remote controller
5021 : Temperature difference between before & after values in “Economic” DHW mode
503
: Time-division multi(TDM) variables for combining operation b/w A2A and A2W
Field Setting Value
Main Menu &
Code
Sub Menu Function Description
Sub
Code
Default Min Max Step Unit
Heating
Code 40✴✴
Heat Pump Heating/DHW Priority ✴✴11 0(DHW) 0 1(Heating) - -
Outdoor Temp for Priority
✴✴12 0 -15 20 1 ˚C
Heating Off
✴✴13 25 14 35 1 ˚C
Overshoot ✴✴14 2 1 4 1 ˚C
Backup Heater Application ✴✴21 1(On) 0(Off) 1 - -
BUH/BSH Priority ✴✴22 0(Both) 0 2(BSH) 1 -
For back-up use only ✴✴23 1(On) 0(Off) 1 - -
Threshold Temp
✴✴24 0 -15 35 1 ˚C
Backup Boiler Application ✴✴31 0(No) 0 1(Yes) - -
Boiler Priority ✴✴32 0(Off) 0 1(On) - -
Threshold Temp
✴✴33 -15 -20 5 1 ˚C
Others
Code 50✴✴
Outing Water Out Temp for
Cooling
✴✴11 25 5 25 1 ˚C
Room Temp for Cooling
✴✴12 30 18 30 1 ˚C
Water Out Temp for
Heating
✴✴13 25 15 55 1 ˚C
Room Temp for Heating
✴✴14 16 16 30 1 ˚C
Auto Cooling WL1 Temp
✴✴15 25 5 25 1 ˚C
Auto Cooling WL2 Temp
✴✴16 25 5 25 1 ˚C
Auto Heating WL1 Temp
✴✴17 15 15 55 1 ˚C
Auto Heating WL2 Temp
✴✴18 15 15 55 1 ˚C
Target Tank Temp
✴✴19 30 30 70 1 ˚C
DHW Saving Mode Temp Difference ✴✴21 5 0 40 1 ˚C
TDM Variable A2A Max Operation Time
✴✴31 30 5 60 5 min
A2W Min Operation Time
✴✴32 3 0 10 1 min