TECHNICAL DETAILS
* Minimum operation flow based on temperature setpoint and inlet conditions.
Infinity Model
Infinity 16i
Units
Installation Internal
G20 Nat Gas Press Low 1.8 mbar
G20 Nat Gas Press High 9.0 mbar
G25 Nat Gas Press Low 1.8 mbar
G25 Nat Gas Press High 9.0 mbar
G30 LPG (Butane) Press Low 2.2 mbar
G30 LPG (Butane) Press High 11.4 mbar
G31 LPG (Propane) Press Low 2.2 mbar
G31 LPG Propane) Press High 14.2 mbar
Height 675 mm
Width 370 mm
Depth 130 mm
Weight 15 kg
Flue System Concentric Forced Draught
Temp. Range Controllers 35 - 60 deg C
Max Temp. via dip switch 75 deg C
Ignition Direct Electronic Ignition
Gas Consumption Low (Gross)
G20 Nat Gas 4.7 kW
0.4
G25 Nat Gas 4.0 kW 0.4
G30 LPG (Butane) 4.9 kW .35
G31 LPG (Propane) 4.9 kW .35
Gas Consumption High (Gross)
G20 Nat Gas 34.9 kW 3.26
G25 Nat Gas 29.6 kW 3.26
G30 LPG (Butane) 36.8 kW 2.6
G31 LPG (Propane) 36.5 kW 2.6
Max Flow raised 25C 15.2 L/min
Min Operation Flow 2.4* L/min
Water Pressure Nom. 1.1 - 7.0 bar
Power Supply
Electric Consumption 68 Watts
230 V / 50 Hz