Rinnai REU - 16 FUA - E Water Heater User Manual


 
33
Dimension Terminal Position Distance
A Directly below an opening, air brick, opening windows, etc. 300mm
B Above an opening, air brick , opening window, etc. 300mm
C Horizontally to an opening, air brick , opening window, etc. 300mm
D Below gutters, soil pipes or drain pipes. 75mm
E Below eaves. 200mm
F Below balconies or car port roof. 200mm
G From a vertical drain pipe or soil pipe. 150mm
H From an internal or external corner. 200mm
I Above ground, roof or balcony level. 300mm
J From a surface facing the terminal. 600mm
K From a terminal facing a terminal 1200mm
L From an opening in a car port. ( eg door, window) into a dwelling 1200mm
M Vertically from a terminal on the same wall. 1500mm
N Horizontally from a terminal on the same wall. 300mm
O From the wall on which the terminal is mounted N/A
P From a vertical structure on the roof. N/A
Q Above an intersection with roof. N/A
UK FLUE REQUIREMENTS - POSITIONING