Installing the water heater:
For increased energy efficiency, use pipe
insulation. Please install the insulation,
according to the figures above, making
sure to insulate all the way to the top. Do
not cover any drain or pressure relief
valve(s).
Do’s
Do follow all installation instructions
covered in this manual.
Do check inlet gas pressure to ensure that
it is within the range specified on the rating
plate.
Do provide adequate air for combustion
and ventilation as discussed in the Use &
Care Manual and the National Fuel Gas
Code (CAN/CGA B149 in Canada).
Do maintain proper clearances to
combustibles and non-combustibles as
specified on the nameplate.
Do ensure that the venting system
complies with the guidelines found in the
Use & Care Manual and National Fuel Gas
Code (CAN/CGA B149 in Canada).
Do contact local gas company to ensure
gas meter and gas piping are adequately
sized.
Do use teflon tape on water line
connections and fittings.
Don’ts
Don’t block or restrict Air Intake
Opening.
Don’t remove the front cover unless
absolutely necessary. This should only be
done after being examined by a qualified
service technician.
Don’t install this product where standing
water may occur.
Don’t use pipe dope on water line
connections and fittings.
During Installation of this water heater...........
Hot and Cold Pipe Insulation Installation
Gas Inle
t
Check Valve
Inlet Pipe
Cold Water
Hot
Water
Insulate all the
way to the top
Insulation Blankets
Insulation blankets, available to the general
public, for external use on gas water heaters
are not necessary. The purpose of an
insulation blanket is to reduce the standby
heat loss encountered with storage tank
heaters. This water heater does not store
water making an insulation blanket
unnecessary.
The manufacturer’s warranty does not cover
any damage or defect caused by installation,
attachment or use of any type of energy
saving or other unapproved devices (other
than those authorized by the manufacturer)
into, onto or in conjunction with the water
heater. The use of unauthorized energy saving
devices may shorten the life of the water
heater and may endanger life and property.
The manufacturer disclaims any responsibility
for such loss or injury resulting from the use
of such unauthorized devices.
CAUTION: If local codes require the
application of an external insulation
blanket to this water heater, pay careful
attention to the following so as not to
restrict the proper function and operation
of the water heater:
Do not cover the air inlet, flue outlet, or
operating and warning labels attached to
the water heater or attempt to relocate them
on the exterior of insulation blanket.
WARNING: If local
codes require external
application of insulation
blanket kits the
manufacturer’s instructions
included with the kit must
be carefully followed.
!
NOTICE: The hot and cold
pipes should be insulated as
shown to provide additional
freeze protection.