26
Regency
®
U39 ULTIMATE Direct Vent Freestanding Gas Stove
7) Reversing step 2 and secure the control
panel back onto the stove pedestal with
the screws.
9) The Ground Wire, DC Sparker Ignition
Wire and Piezo Spark Wire all go
through the hole located on the pedestal
back cover.
10) Put on the plastic split bushing.
11) Attach the Piezo Ignition Wire to the
back of the DC Sparker box.
14) Connect the DC Sparker Ignition Wire to
the DC Sparker.
12) The ground wire and DC Sparker
ignition go through the hole on the heat
shield.
18) We recommend mounting the DC Sparker
box onto the pedestal back cover.
19) Check for gas leaks.
20) Check inlet and outlet pressures.
21) Check operation of fl ame control.
22) Check for proper fl ame appearance and glow
on logs.
6) Secure with screw.
8) Attach one end of the green ground wire
to the grounding stud on the inside of
the pedestal.
13) Apply the plastic bushing to the heat
shield hole.
15) Attach the green ground wire.
17) Place the heat shield over the DC Sparker.
green ground wire
16) Install the supplied battery into the DC Sparker
Box by opening the battery compartment.
NOTE: The battery in the DC Sparker Box will
need to be replaced annually.
Battery
Compartment
INSTALLATION