Regency U32S-NG5 Indoor Fireplace User Manual


 
13U32S-5 FPI Direct Vent Gas Insert
INSTALLATION
4) Connect the DC spark generator wires
to the SIT Valve with the screw, which is
provided in the kit.
5) Locate the ground lug at the receptical
box, left of the unit.
6) Connect one end of the supplied green
ground wire to the lug with the nut and
washer from the kit.
9) Plug the DC spark generator wires to the
DC Sparker.
10) Connect the ground wire to the DC
Sparker mounting bracket.
12) Mount the heat shield to the DC Sparker.
Secure into place with the velcro, which
is provided in the kit.
7) Install the 1/2" bushing to the heat
shield.
13) Find a location which is not too hot and is
easy to reach for changing the battery.
Note: It should be kept away from the
chain.
14) Tie up the loose wire with the wire clip.
Ground
wire from
kit
Chain
1) Locate the Piezo Ignitor situated at the
side of valve.
2) Remove the Piezo Ignitor by unscrewing
the nut at the back of the mounting
bracket.
3) Disconnect the ignitor wire from the
Piezo Ignitor and connect it to the DC
Sparker.
Ignitor
Wire
Piezo
Ignitor
Ignitor
Wire
DC
Sparker
Heat Shield
8) Run the other end of the ground wire
and DC spark generator wires through
the bushing on the heat shield.
Installation of the DC Sparker
11) Install the supplied battery into the DC
Sparker Box by opening the battery
compartment.
NOTE: The battery in the DC Sparker
Box will need to be replaced annually.
Battery
Compartment
Piezo ignitor