INSTALLING VALVE
8) Reinstall the 12 hold down screws.
9) Hook up the 2 TP and 2 TH wires to the appropriate connections on
the valve.
10) Reinstall the burner grate. Put a dab of high temperature silicone
over the 3 screw holes.
11) Install Burner tube.
12) Hook up the gas line and check for gas leaks with a soap and water
solution or a gas leak detector. (Do not use open fl ame for leak
testing.)
13) Fire up the unit.
14) Check the manifold pressure.
15) Reinstall the vermiculite, embers, rockwool and logs as needed.
16) Install and close the door and replace the louvers.
MAINTENANCE
1) Attach the valve bracket to the valve with the 4 (m5x8 metric) screws
provided.
2) Reconnect the "gas out" 90
o
elbow fl are fi tting with an 11/16"
wrench.
3) Reconnect the "gas out" fl are nut with a
13/16" wrench.
4) Reconnect the quick drop out thermocouple nut with a 9mm
wrench.
5) Reconnect the pilot tube nut with a 7/16" wrench.
6) Scrape off the old gasket from the fl oor of the fi rebox.
7) Install a new gasket and reinstall the valve assembly.
Note: Failure to install a new gasket may severely affect the
appliance performance.