Regency P42-NG4 Indoor Fireplace User Manual


 
Regency
®
P42-4 Zero Clearance Direct Vent Gas Fireplace 11
6-7/8"
(173mm) dia.
Flue pipe
4" (102mm)
dia. flue pipe
Termination Cap
Part #946-523/P
AstroCap
spring
spacer
Wall Thimble (2 pc)
INSTALLATION
VENTING
Regency
®
Direct Vent System (Flex) Horizontal Terminations Only
These venting systems, in combination with the P42 Direct Vent Gas
Fireplace, have been tested and listed as a direct vent heater system
by Warnock Hersey. The location of the termination cap must conform to
the requirements in the Vent Terminal Locations diagram in the "Exterior
Vent Termination Locations" section.
Regency
®
Direct Vent (Flex) System Termination Kit (Part # 946-515)
includes all the parts needed to install the P42 with a maximum
run of 4 feet.
1) 6-7/8" dia. fl exible liner (4 ft. length)
2) 4" dia. fl exible liner (4 ft. length)
3) spring spacers (4)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1/2" Drill Point, stainless steel (4)
If longer runs are needed, the Regency
®
Direct Vent system (Flex)
# 946-516 includes all the parts needed to install the P42 with a
maximum 10' run.
1) 6-7/8" dia. fl exible liner (10 ft. length)
2) 4" dia. fl exible liner (10 ft. length)
3) spring spacers (7)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1/2" Drill Point, stainless steel (4)
Note:
a) Liner sections should be continuous without any joints or seams.
b) Only Flex pipe purchased from Regency
®
may be used for Flex
Installations.