Regency F39-NG Stove User Manual


 
Regency
®
F39 Room Sealed Freestanding Gas Stove
25
Mitred Glass Replacement
Removing Glass
1) Remove the door from the unit and place
on a soft surface to prevent scratching.
2) Pull out the door gasket.
3) Remove the 24 nuts holding the glass
retainers in place. Do not remove the nuts
underneath the retainers.
4) Remove the door catch plate.
5) Remove glass retainers on sides fi rst (3 each
side) then remove two center retainers.
Note: Center glass retainers are glued to
center glass.
6) Remove glass from extrusions. When re-
moving center glass, leave white insulation
in place.
Installing Glass
2) Place glass assembly into door frame.
3) Install retainers by placing 1 drop of glue
where previously glued and put in place.
4) Install side retainers.
5) Install door catch plate.
6) Install the 24 nuts loosely, do not tighten
yet.
1) Install both center
and side glass
onto extrusions
as per diagram.
Panel Glass Door Assembly
Wraparound Assembly Door
(same glass retainers as the
Panel Assembly)
Note: Wearing gloves will protect your hands
while handling glass.
Panel Glass Replacement
1) Remove the door from the unit and place on
a soft surface to prevent scratching.
2) Pull out the door gasket.
3) Remove the nuts holding the glass retainers
in place.
4) Remove the glass retainers (sides, top and
bottom) and the door catch plate.
5) Replace the glass. The glass must have
gasketing around it.
6) Reverse the previous steps, replace the
retainers and fasten with the nuts but do
not overtighten, as this can break the glass.
Note: the door catch plate fi ts on top of the
left side retainer.
7) Put gasket glue on the retainers, but do not
put glue on the screws. Replace the door
gasket, the two ends butt tight together on
the bottom edge of the door.
8) Replace door on the stove and check the
seal.
LOG REPLACEMENT
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door to carefully remove the
logs. The pilot light generates enough heat to
burn someone. If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagram under Log
Installation.
Note: Improper positioning of logs may
create carbon build-up and will alter
the unit’s performance which is not
covered under warranty.
DOOR GASKET
If the door gasket requires replacement use 7/8"
diameter oval door gasket (Part # 650-920).
LATCH ADJUSTMENT
The door latch may require adjustment as the
door gasket material compresses after a few fi res
and after glass replacement. Turn the adjustable
catch to tighten or loosen the latch.
GLASS REPLACEMENT
Your Regency
®
stove is supplied with high tem-
perature, 5 mm Neoceram ceramic glass that
will withstand the highest heat that your unit will
produce. In the efl ue that you break your glass
by impact, purchase your replacement door from
an authorized Regency
®
dealer only, and follow
our step-by-step instructions for replacement.
The glass is not sold separately, as it must be
properly sealed in the door frame.
Replacement Part #
940-325/P F39 Wraparound Glass
940-322/P F39 Panel Center Glass
940-323/P F39 Panel Side Glass
WARNING: Do not operate appliance
with glass panels removed, cracked
or broken. Replacement of the glass
should be done by a licensed or
qualifi ed service person.
MAINTENANCE