Regency F39-NG Stove User Manual


 
16
Regency
®
F39 Room Sealed Freestanding Gas Stove
Burner Inlet Orifi ce Sizes:
NG LPG
Burner #32 #50
2.95mm 1.78mm
Max. Input NG 40 Mj/h
LPG 38 Mj/h
Min. Input NG 20 Mj/h
LPG 19 Mj/h
Supply Pressure
NG min. 1.13 kPa
LPG min. 2.75 kPa
Manifold Pressure
NG .94 kPa
LPG 2.55kPa
Electrical: 240 V. 1.13A 60Hz.
Circulation: 2 speed fan, 125/75 CFM.
Log Set: Ceramic fi ber, 7 per set.
System Data
F39 Converted to 31mj
Burner Inlet Orifi ce Sizes:
NG #37 2.65mm
LPG #52 1.6mm
Max. Input - NG/LPG
31 Mj/h
Min. Input - NG/LPG
16 Mj/h
Supply Pressure
NG min. 1.13 kPa
LPG min. 2.75 kPa
Manifold Pressure
NG .89 kPa
LPG 2.55kPa
Electrical: 240 V. 1.13A 60Hz.
Circulation: Variable speed fan, 125/75
CFM.
Log Set: Ceramic fi ber, 7 per set.
System Data
F39 with 40mj
INSTALLATION
Note: To properly check gas pressure, both
inlet and manifold pressures should
be checked using the valve pressure
ports on the valve.
1) Make sure the valve is in the "OFF" posi-
tion.
2) Loosen the "IN" and/or "OUT" pressure
tap(s), turning counterclockwise with a 1/8"
wide fl at screwdriver.
3) Attach manometer to "IN" and/or "OUT"
pressure tap(s) using a 5/16" ID hose.
4) Light the pilot and turn the valve to "ON"
position. Read manometer.
5) The pressure check should be carried out
with the unit burning and the setting should
be within the limits specifi ed on the safety
label.
6) When fi nished reading manometer, turn
off the gas valve, disconnect the hose and
tighten the screw (clockwise) with a 1/8" fl at
screwdriver. Note: Screw should be snug,
but do not over tighten
Valve Description
1) Gas on/off knob
2) Manual high/low adjustment
3) Pilot Adjustment
4) Thermocouple Connection
5) Main Operator
6) Outlet Pressure Tap (Manifold
Pressure)
7) Inlet Pressure Tap (Supply
Pressure)
8) Pilot Outlet
9) Main Gas Outlet
10) Flange Securing Screw Holes
11) Alternative TC Connection Point
12) Thermoelectric Unit
13) Additional Valve Mounting Hole
AERATION
ADJUSTMENT
The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude.
F39 with 40mj
F39-NG NG: Full open
F39-LPG LPG: Full open
F39 with 31mj
F39-NG NG 6mm open
F39-LPG LPG 10mm open
Note: Any damage due to carboning resulting
from improperly setting the aeration
controls is NOT covered under war-
ranty.