Regency F39-NG Stove User Manual


 
10
Regency
®
F39 Room Sealed Freestanding Gas Stove
INSTALLATION
DV STOVE HORIZONTAL FLUE KIT (# 946-112) INSTALLATION
Minimum Installation Height:
F39: 59-3/4" ( 1518mm)
Review the following sequence of instructions
which are typical of most installations. The
sequence may vary depending on wall thick-
ness. Refer to fl ue location, see "Exterior
Flue Termination Location" section. and
clearance dimensions, see to "Clearances
to Combustibles" section.
1) Set the unit in its desired location. Check
to determine if wall studs will be in the way
of the fl uing system, adjust location until
all clearances are met and there are no
obstructions.
Note: A 1-1/2"(38mm) clearance around
the outer pipe must be maintained
except that only a 1" (25mm) clear-
ance is needed at the termination
end.
IMPORTANT:
Do not locate termination hood where
excessive snow or ice buildup may occur.
Be sure to check fl ue termination area after
snow falls, and clear to prevent accidental
blockage of fl uing system. When using
snow blowers, make sure snow is not directed
towards fl ue termination area.
2) Assemble a trial fi t to determine the verti-
cal center-line for the fl ue termination.
a) Cut a 241mm round hole on both the
interior and exterior wall.
b) Attach the 2 ft. pipe section to the fl ue
terminal and slide into position from
the exterior. The larger diameter end
of the adjustable pipe goes to the
ue terminal.
c) Install the 90
o
elbow onto the adjust-
able pipe to determine the vertical
centerline of the starter collar on the
unit.
Note: if the centerline cannot be
met, the adjustable sections will
have to be cut.
d) Cut the 2 ft. section of rigid pipe to
length. Ensure that the pipe length
DV STOVE HORIZONTAL FLUE KIT
Horizontal Stove Flue Kit (Part # 946-112) includes all the parts needed to install the F39 Freestand-
ing Gas unit with minimum horizontal and vertical vent dimensions. For installations that require
longer vertical and/or horizontal vents use the Dura-Vent system as shown in your manual.
Qty. Description
1) 2 Rigid Pipe Section 1.2m length, 165mm inside diameter
2) 1 Flex Liner, compressed aluminium 2 ply liner, 102mm inside diameter
3) 4 spring spacers
4) 1 90 deg. Elbow
5) 1 Decorative Wall Trim
6) 1 Adapter
7) 1 AstroCap Termination Cap
8) 2 Trim Collar
9) 1 tube of Mill-Pac, high temperature sealant
10) 12 Screws, #8 x 1/2" Self tapping, Stainless Steel
11) 14 Screws, #8 x 1/2" Self tapping, Black
12) 4 Screws #8 x 1-1/2" Drill Point, Stainless Steel
Optional:
946-206 Vinyl Siding Standoff
for AstroCap
Note:
a) Liner sections should be continuous
without any joints or seams.
b) This is an approved system, therefore
components in this system must not be
substituted for any other manufacturer's
products.
c) Wall Thimble is required when installing
through a combustible wall.