Regency F39-NG Stove User Manual


 
18
Regency
®
F39 Room Sealed Freestanding Gas Stove
LOG SET
INSTALLATION
Read the instructions below carefully and
refer to the diagrams. If logs are broken
do not use the unit until they are replaced.
Broken logs can interfere with the pilot
operation.
The gas log kit contains the following:
a) 02-65 Rear Log
b) 02-56 Middle Left Log
c) 02-44 Front Left Log
d) 02-46 Left Top Log
e) 02-45 Front Right Log
f) 02-47 Center Log
g) 02-48 Middle Right Log
h) Embers 902-151
i) Lava 902-154
Note: Install Optional Brick Panels prior to
installing logs.
Embers Embers
The "02" refer numbers (i.e. 02-65) are
molded into the rear of each log.
1) Carefully remove the logs from the box and
unwrap them. The logs are fragile, handle
with care - do not force into position.
2) Sprinkle the embers on the left and right
sides of the fi rebox base.
INSTALLATION
CONVERSION TO LOWER BTU RATING
THIS CONVERSION MUST BE DONE BY AN AUTHORIZED GAS
FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
NG Conversion Kit 730-920
Contains:
Qty. Part # Description
1 904-240 Burner Orifi ce #37 (NG)
1 918-034 Decal "Converted to 30,000 Btu"
1 918-033 Instruction Sheet
LPG Conversion Kit 730-922
Contains:
Qty. Part # Description
1 904-390 Burner Orifi ce #52 (LPG)
1 918-034 Decal "Converted to 30,000 Btu"
1 918-033 Instruction Sheet
Additional Piece (pkg. with unit:
1 Log Bracket Restrictor
1) Shut off the gas supply.
2) Open the front door. Carefully remove the
logs and lava rock.
3) Remove burner. See diagram below.
Burner Orifi ce
4) Unscrew the 2 Rear
Log Pins and move
to the front hole posi-
tion.
5) Remove Rear Log
Bracket and slide the
Log Bracket Restric-
tor between the Rear
Position the Log Bracket Restrictor between
the Rear Log Bracket and the burner.
6) Remove burner orifi ce with a 1/2" spanner
and discard.
7) Reinstall new burner orifi ce (NG stamped
#37 or LPG stamped #52) and tighten.
8) Reverse steps 3) and 2).
9) Adjust Flue restrictor setting: To set the Flue
restriction as indicated in the diagram, simply
loosen the screws and push the fl ue restric-
tor plate to the correct position. Tighten the
screws.
Unit Btu/h Restrictor Opening
F39 40 Mj/h A 45mm
31 Mj/h B 35mm
Note: Use a magnetic
type screwdriver if
possible.
Log Bracket and the burner, secure with the
2 screws.
Flue Restrictor set-
ting at High Btu/h
Flue Restrictor set-
ting at Low Btu/h
10) Attach the label "This unit has been con-
verted to..." on top of the data badge over
the higher Btu information.
11) Check for gas leaks.
12) Check inlet and outlet pressures.
13) Check operation of fl ame control. Check for
proper fl ame appearance on logs.