2.2.1 Additional Safety systems
Depending on the kind of application it may be useful to have additional sensors as safety
features. This is especially true for a door with a high volume of human traffic or with low
sized doors with a height under 10 feet (3m).
Albany Door Systems offers a variety of safety systems for high-speed doors. Some
examples could be any of the following: Light beam barriers, motion detectors, induction
loops. For any other electrical requirement contact us at the factory.
2.3 Drives
The Re-Coil-Away is operated with an electrical drive. Drive side is chosen by the end-user.
The drive system has a 1-speed operator. The drive systems come in 3 different operating
voltages: 208 VAC, 460 VAC, and 575 VAC.
2.4 Technical Data
Door principle: Roll door
Running direction: Vertical
Application:
External door
(also applicable as interior door)
Maximum Sizes: 18’ wide x 18’ high
Maximum opening speed:
18 inches per second @ 8 feet
(Depends on door size)
Maximum Closing speed:
18 inches per second @ 8 feet
(Depends on door size)
Fitting position: Interior or external mounting
Drive: Electrical
Electric Power: 208VAC, 460VAC, 575VAC
Maximum Horse power: 2.0 H.P.
Control unit: Built-in operator controls
Control voltage 24VDC
Motor protection category: IP54 - NEMA 12
Door frame: Painted Steel
Curtain: SBR, EPDM
Door dimensions and fitting space See enclosed technical drawing
Fixing points: See fixing drawings
Technical changes resulting of product maintenance are subject to alterations