6.6 Maintenance Schedule
Due to the unique design features of your new "RE-COIL-AWAY", the need for continual
maintenance normally associated with conventional door systems (i.e.: guide rollers, hinges,
door track, etc.) is virtually eliminated. The limited maintenance procedures listed below,
when completed as indicated, will assure many years of trouble-free operation.
MAINTENANCE
PROCEDURE
INTIAL
1,500
CYCLES
EVERY 25,000
CYCLES OR 3
MONTHS
EVERY 50,000 CYCLES
OR 12 MONTHS
LUBRICATE:
Flange Bearing (4)
Drive Chain
NO
NO
NO
OIL
Grease, 1 shot
OIL
ADJUSTMENTS:
Drive Chain Tension
Brake band, Solenoid
Guides, bottom bar &
header assembly for
rust or damage
Guide Opening 1/2"
All Fasteners (check
for tightness)
Limit Settings
Reversing Edge
(check for proper
operation and any
signs of damage)
YES
YES
YES
NO
YES
YES
YES
YES
YES
YES
YES
YES
YES
EVERY MONTH
YES
YES
YES
YES
YES
YES
YES, every 350,000 cycles
Service & Repair