Raymarine M81166 Water Pump User Manual


 
Constant Running Hydraulic Pump - Installation Guide 5
Installation instructions
Parts required
To install this drive you will need:
Parts supplied:
CR hydraulic pump
if required: BSP to NPT adaptors (x3)
Additional parts:
suitable hydraulic pipes, hydraulic fluid, T-pieces, pipe
fittings and thread-sealing compound (see page 8)
suitable securing bolts, lock washers/lock nuts (see page 7)
suitable cable and electrical connectors for the drive motor
and solenoid control valves (see page 13)
CR interface (to connect to Type 100/300 course computer)
bypass valve (if connecting to a secondary steering ram)
Note: Obtain these additional parts before you start installation.
Installation steps
WARNING: Electrical safety
Make sure you have switched off the power supply before you
start installing this product.
Follow these steps to install your CR pump:
Ï
Ï
Ï
Ï
1
Consult the EMC installation guidelines. page 6
2
Mount the pump. page 7
3
Connect to the hydraulic steering system. page 8
4
Connect to the course computer. page 13
5
Complete the post-installation checks. page 16