Quadra-Fire SAPPHIRE-D-PMH Stove User Manual


 
14
Quadra-Fire • Sapphire • 7055-116 Rev. D • 6/11
Step 5.
Place the wall thimble cover over the pipe assembly and
slide the appliance and vent assembly towards the wall,
carefully inserting the vent pipe into the vent termination
cap assembly. It is important that the vent pipe extend into
the vent termination cap a sufficient distance so as to result
in a minimum pipe overlap of 1-1/4 in. (32mm). Secure the
connection between the vent pipe and the vent termination
cap by attaching the two sheet metal strips extending from
the vent termination cap assembly into the outer wall of
the vent pipe. Use the two sheet metal screws provided to
connect the strips to the pipe section. Figure 5.10.
Note: The attachment from the vent pipe to the vent cap
must be sealed with silicone. Venting terminals shall not be
recessed into a wall or siding.
Wall Thimble Cover
Wall Thimble
Vinyl siding standoff with siding beneath
removed
Screws
Bolt horizontal top to vinyl
standoff
Screws
Apply sealant to all four sides
Vinyl Siding
Figure 5.9
(NOTE: Some termination caps may cause the vent
pipe to be off center on flashing). Ensure that proper
clearances to combustible materials are maintained.
If you are not using an approved termination cap with
a built-in standoff on a building with vinyl siding, a
vinyl siding standoff should be installed between the
termination cap and the exterior wall (Figure 5.9).
Follow manufacturer’s instructions for attaching the
vinyl siding standoff to the horizontal termination cap.
The vinyl siding standoff prevents excessive heat from
possibly melting the vinyl siding material. . Remove
siding from the area where the standoff will be located.
Burn Risk.
Local codes may require installation of a
cap shield to prevent anything or anyone
from touching the hot cap.
WARNING
WARNING
Do NOT connect a pipe section to a termination cap without
using the telescoping ue section found on the termination cap.
Fire Risk.
Exhaust Fume Risk.
Impaired Performance of Appliance.
WARNING
Ensure vent components are locked together correctly.
Pipe may separate if not properly joined.
Fold Strap
Here
Wall Thimble Cover/Ceiling
Firestop as Required by Local
Jurisdiction
1/4 in. (6mm)
Strap
Sheet Metal Screw
Wall Thimble
Figure 5.10
WARNING! The vent terminal cap shall not be recessed
into a wall or siding