C. Junction Box Installation
Figure 10.3 Junction box installation
JUNCTION
BOX
SIDEWALL
FEED PLUG
THROUGH HOLE
INSERT STRAIN RELIEF
AROUND CORD IN THIS END
FROM OUTSIDE OF UNIT
SCREW
PROVIDED
Optional Accessories
Connecting the electrical junction box is required if using
a blower or remote.
• Plug the cord into a convenient outlet.
• Must use cord supplied.
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.
D. Fan Replacement
On units already installed removal of decorative front,
surround and gas insert is required.
• Detach fl exible liner from back of unit if insert is in-
stalled.
• Remove the four screws on the cover plate (see Figure
10.4).
Figure 10.4
FAN
COVER
PLATE
POWER
CORD
GROUND
WIRE
• Remove the old fan. See Figure 10.5.
• Place the new fan in between the bend up tabs.
• Install and wire the fan per instruction shipped with the
fan.
• The ground wire of the fan can clip on the side of the
base pan.
• Reinstall the cover plate back on the unit. Make sure the
fan does not make contact with the back wall to prevent
noise from vibration.