Quadra-Fire • QVI-35FB-S • 2178-900 Rev. B • 12/08 25
ON
OFF
ON/OFF
SWITCH
REMOTE SWITCH
PIGTAIL
OPTIONAL WALL SWITCH,
THERMOSTAT OR REMOTE
STANDING
PILOT
WHT
RED
VALVE
B. Standing Pilot Ignition System Wiring
• The standing pilot ignition system wiring DOES NOT
require a 110 VAC supply to operate.
• A 110 VAC junction box MUST be installed for use with
a fan or remote control. See Figure 10.3 for junction box
wiring. Keep wire lengths short as possible.
NOTICE: DO NOT wire 110 VAC to the millivolt valve! This
will damage the valve.
• If using a thermostat use one compatible with a millivolt
gas valve system:
- Install the thermostat in the location as indicated in the
thermostat instructions to ensure proper operation of
appliance.
- Use low resistance thermostat wire for wiring from
ignition system to the wall switch and thermostat.
- Keep wire lengths short as possible by removing any
excess wire length.
A. Wiring Requirements
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
• Wire the appliance junction box to 110-120 VAC. This is
required for use of optional accessories (standing pilot
ignition).
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when it is
installed in locations such as in bathrooms or near sinks.
• Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT wire
110V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.
• This appliance uses a standing pilot ignition system.
• Open the control access panel.
• A red or black ignitor button (as shown in Figure 10.1)
indicates this appliance is standing pilot ignition.
10
10
Electrical Information
ON/OFF Switch
• An ON/OFF switch is included with appliance and should
attached to surround/facing. (See Installation instructions
for remote control).
• If desired an additional wall switch or thermostat may
be added to system as shown in Figure 10.2).
Figure 10.2 Standing Pilot Ignition Wiring Diagram
IGNITOR BUTTON
Figure 10.1 Location of Ignitor Button