Quadra-Fire QVI-30FB-S Indoor Fireplace User Manual


 
Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09
32
14
14
Maintaining and Servicing Appliance
Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a quali ed
service technician should perform an appliance checkup at the beginning of each heating season.
Annual inspection by quali ed technician recommended.
Check:
Condition of doors, surrounds and fronts.
Condition of glass, glass assembly and glass seal.
Obstructions of combustion and ventilation air.
Condition of logs.
• Condition of rebox.
Burner ignition and operation.
Burner air shutter adjustment
Gas connections and ttings.
Obstructions of termination cap.
Clean:
• Glass
Air passageways, grilles,
control compartment
Burner, burner ports
Risk of:
• Fire
Delayed ignition or explosion
Exposure to combustion fumes
• Odors
Handle glass assembly with care.
NOTE: Clean glass after initial 3-4 hours operation.
Longer operation without cleaning glass may
cause a permanent white lm on glass.
CAUTION
When cleaning glass door:
Avoid striking, scratching or slamming glass.
Do NOT use abrasive cleaners.
Use a hard water deposit glass cleaner on white lm.
Do NOT clean glass when hot.
• Turn off appliance after 3-4 hours of operation and
ALLOW TO COOL.
Remove and clean glass assembly.
• Replace glass assembly and operate appliance for
additional 12 hours.
Refer to maintenance instructions.
Risk of injury or property damage.
Before servicing:
Turn off gas.
Turn off electricity to appliance.
Disable remote control, if one is present.
Ensure appliance is completely cooled.
After servicing:
Replace any screen or barrier that was removed.
Reseal and reinstall any venting removed for servicing.
Inspect external vent cap regularly.
Ensure no debris blocks cap.
Combustible materials blocking cap may ignite.
• Restricted air ow affects burner operation.
WARNING
WARNING
WARNING
A. Maintenance Tasks