Quadra-Fire QVI-30FB-S Indoor Fireplace User Manual


 
Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09
12
A. Venting Components
7
7
Installing Vent Pipe and Appliance
The vertical vent termination system installed on this model
includes:
One 3-foot section stainless steel exible pipe (included
with insert).
One length of 3-inch exible vent pipe for combustion air
(included with vent kit).
• Flexible vent pipe for exhaust air (included with vent kit).
• One pipe-to-cap adaptor (included with vent kit).
• One vertical termination cap (included with vent kit).
Figure 7.1
B. Connecting Vent Pipe
Reference instructions in the termination kit.
• Install the 3-inch exible vent pipe(s) down through the
chimney.
Secure the exhaust exible vent pipe to the 3 foot section
stainless steel flexible vent pipe using the factory-
installed 3-inch collar in the stainless steel section of
pipe (see Figure 7.1).
• Use 3 screws to attach either a 4 foot or 30 foot section
of inlet air vent to the inlet collar on the collar slide plate
(see Figure 7.1). NOTE: The collar slide plate may be
removed from appliance to aid installation.
Seal opening between ex vent and chimney just above
insert. Unfaced berglass insulation may be used for this
purpose.
CAUTION
Sharp Edges
Wear protective gloves and safety
glasses during installation.
TERMINATION
CAP
ADAPTOR
EXHAUST
VENT PIPE
V= 14 FT. MINIMUM
50 FT. MAXIMUM
3 INCH COLLAR
(Factory installed to
stainless steel section)
WARNING: DO NOT
BLOCK PIPE END WITH
INSULATION OR ANY OTHER
SEALING MATERIAL
STAINLESS STEEL
PIPE - 3 FT. MIN.
REQUIRED (INCLUDED)
INLET AIR
VENT PIPE
COLLAR ATTACHMENT
BRACKET
EXHAUST COLLAR
INLET AIR COLLAR
Note: To achieve optimum
performance of insert,
minimize or avoid bends
in exhaust vent pipe.