CB1200-I Pellet Insert
2
Getting Started
A
.
Design, Installation & Location Consider-
ations
Warning! Risk of Fire Damaged parts could impair safe
operation. Do NOT install damaged, incomplete or substitute
components.
1. Appliance Location
NOTICE: Check
building codes prior to installation.
Installation MUST comply with local, regional, state and
national codes and regulations.
Consult insurance carrier, local building inspector, re
ofcials or authorities having jurisdiction over restrictions,
installation inspection and permits.
It is a good idea to plan your installation on paper, using
exact measurements for clearances and oor protection,
before actually beginning the installation
Consideration must be given to:
Safety, convenience, trafc ow
Placement of the chimney and chimney connector.
If you are not using an existing chimney, place the appli-
ance where there will be a clear passage for a factory-
built listed chimney through the ceiling and roof.
Installing an optional outside air kit would affect the loca-
tion of the vent termination.
CAUTION!
Ifburningshelledeldcorn,youmustuseap-
provedventingspecicallydesignedforcorntopreventcorro-
sion or degradation. Follow the instructions from the venting
manufacturer.
Since pellet exhaust can contain ash, soot or sparks, you
must consider the location of:
Windows
Air Intakes
Air Conditioner
Overhang, softs, porch roofs, adjacent walls
Landscaping, vegetation
When locating vent and venting termination, vent above roof
line when possible.
Marginal Location:
• Below peak
Location NOT recommended:
• Not the highest point of the roof
• Wind loading possible
Multi-level Roofs
Windward
Leeward
Recommended:
Outside Air Intake
on windward side
NOT recommended:
Outside Air Intake
on leeward side
Recommended Location:
• Above peak
Recommended:
• Insulated exterior chase
in cooler climates
Recommended Location:
• Above peak
• Inside heated space
Location NOT recommended:
• Too close to tree
• Below adjacent structure
• Lower roof line
• Avoid outside wall
Marginal Location:
Wind loading possible
NOTICE: Locating the appliance in a location of
considerable air movement can cause intermittent smoke
spillage from appliance. Do not locate appliance near:
Frequently open doors
Central heat outlets or returns
Figure 5.1