Quadra-Fire CB1200MI-MBK Indoor Fireplace User Manual


 
R
R
R
February 3, 2010
7014-188B
Page 27
CB1200-I Pellet Insert
C. Before Your First Fire
1. First, make sure your appliance has been properly
installed and that all safety requirements have been met.
Pay particular attention to the re protection, venting and
thermostat installation instructions.
2. Double check that the ash pan and rebox are empty!
3. Check the position of the thermocouple, located above
the repot, and make sure that it protrudes approximately
3/4 inch (19mm) into the repot.
4. Close the front door.
D. Starting Your First Fire
1. A thermostat is required for proper operation of this
appliance, except for corn. At this time, ll the hopper
with pellets, set the thermostat to its lowest setting. Plug
the power cord into nearby outlet.
2. The exhaust blower will stay on for approximately 10
minutes even though the thermostat is not calling for
heat. This is normal.
3. L
ocate the heat output control switch on the right side
behind the right side panel. Set to the HIGH setting and
then adjust the thermostat to its highest setting. The
red call light will be on which is located on the right side
behind the right side panel. This indicates the thermostat
is calling for heat. Figure 27.1.
4.
The fuel feed system and the igniter should
now
be on.
5. For your rst re it will be necessary to press the reset
button approximately 2 minutes after start-up and again
at 4 minutes. This will ll the feed system and allow the
appliance to begin dropping pellets. Continue pushing
the reset button until you detect that pellets are being
delivered into the repot. The appliance will continue to
run as long as the thermostat is calling for heat.
6. Once the appliance has ignited, let the it burn for
approximately 15 minutes, then set the thermostat to the
desired room temperature. Adjust the heat output control
switch to the desired setting.
Odors and vapors released during initial operation.
Curing of high temperature paint.
Open windows for air circulation.
Odors may be irritating to sensitive individuals.
CAUTION
CAUTION
Tip of thermocouple must be in contact with the inside
end of the thermocouple cover.
Missed ignitions can occur.
B. General Operating Information
1. Thermostat Calls For Heat
The appliance is like most modern furnaces; when the thermostat
calls for heat, your appliance will automatically light and deliver
heat. When the room is up to temperature and the thermostat
is satised, the red call light will shut off and the appliance will
shut down. Figure 27.1.
2. Heat Output Controls
Figure 27.1
Heat Output Switch
Reset Button
Red Call Light
Fuse
Control Box
Red / Green
Light
Blue
Blinking
Light
This appliance is equipped with a heat output control switch that
has three settings or burn rates; low, medium and high. The
appliance will turn on and off as the thermostat demands. When
the thermostat calls for heat, the appliance will always start up
on High. After burning approximately 4 minutes, the appliance
will then burn at the rate at which it was originally set. If the
appliance is set at one of the lower settings, it will run quieter
but takes longer to heat up an area than if it were set at a higher
burn rate. Regardless of the burn rate, when the area is warm
enough to satisfy the thermostat, the appliance will shut off.
WARNING
Fire Hazard.
Keep combustible materials, gasoline
and other ammable vapors and liquids
clear of appliance.
Do NOT store ammable materials in the appliance’s
vicinity.
DO NOT USE GASOLINE, LANTERN FUEL, KEROSENE,
CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO
START OR “FRESHEN UP” A FIRE IN THIS HEATER.
DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS
SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL.
DO NOT USE CHEMICALS OF FLUIDS TO START THE
FIRE.
Keep all such liquids well away from the heater while it is in
use.
Combustible materials may ignite.