Page 28
7014-188B
February 3, 2010
R
CB1200-I Pellet Insert
R
R
WARNING
Fire Risk
Do NOT operate appliance:
• With appliance door open.
• Firepot oor open.
• Cleaning slide plates open.
Do NOT store fuel:
•
Closer than required clearances to com-
bustibles to appliance
• Within space required for loading or ash
removal.
Back side of Firepot
Firepot floor left open
Figure 28.1 - DO NOT LEAVE FIREPOT FLOOR OPEN
E. Fire Characteristics
A properly adjusted re with the heat output control switch set
on “HIGH” has a short active ame pattern that extends out
of the repot approximately 4 to 6 inches (102-105mm). If
the re has tall ames with black tails and seems somewhat
lazy, the feed rate will need to be reduced. If the re is not 4
inches to 6 inches (102-105mm) tall, increase the feed rate.
A medium and low setting will give a shorter ame. The ame
will rise and fall somewhat. This is normal.
The feed adjustment control rod is factory set, and should
be adequate for most fuels.
The set screw is located at the
bottom of the hopper and set loose at the factory so the fuel
adjustment control rod will slide by only loosening the wing
nut. Do not re-tighten bottom set screw.
However, if the flame height is too high or too low, you will
F. Feed Rate Adjustment Instructions
need to adjust the feed rate. Wait until the appliance has been
burning for 15 minutes before making your adjustments and
a
llow 15 minutes for feed adjustment to take effect.
1. Open the hopper lid and locate the fuel adjustment control
rod.
2. Loosen the wing nut on the rod.
3. Adjust the fuel adjustment control rod towards the "+"
symbol to increase the feed rate and ame height or
towards the "-" symbol, to decrease the feed rate and
flame height. Make approximately 1/2 inch (13mm)
movements of rod at a time.
4. Re-tighten the wing nut.
G. Ignition Cycles
1. During each ignition cycle, it is normal to see some smoke
in the rebox. The smoke will stop once the re starts.
2. The convection blower will automatically turn on after your
appliance has reached the set temperature. This blower
transfers heat from your appliance into the room, and will
continue to run after the thermostat has stopped calling
for heat until the appliance has cooled down.
3. Occasionally the appliance may run out of fuel and shut
itself down. When this happens, the red call light will be
on. To restart it, ll the hopper and press the reset button.
When you press the reset button the red call light will go
out. Release the button and the light will come back on.
You should see a re shortly. If not, follow the instructions
“Starting Your First Fire”.on this page.