7100FP EPA Woodburning Fireplace
Diagnostic Question Possible Causes of Condition Solutions
Are the air controls open? No draft
No combustion air
Open air controls
Is there enough paper? Insuf cient heat to ignite kindling Use more paper
Is there enough kindling?
Is the kindling dry?
Insuf cient heat to ignite fuel Use drier kindling
Is there enough or too much wood?
Is it too large?
Is it dry enough?
• Insuf cient heat to establish draft
• Insuf cient air passage
• Insuf cient surface area
Ignition temperature high due to
moisture
Use small split wood that is well sea-
soned (split, covered on top minimum 6
months, preferably a year)
Are there adequate air spaces
between fuel pieces?
Insuf cient combustion air and exposed
surface area
Arrange kindling and wood for air move-
ment
Is the chimney pre-warmed? Exposed, cold chimney downdrafting Use lighted rolled newspaper at ue
opening to start upward air movement
Is there smoke in the house? Obstruction in chimney
Downdraft from chimney tempera-
ture or from negative house pres-
sure
Have chimney checked if it worked
previously
• Pre-warm chimney
Shut off exhaust devices
• Open window slightly
Does the kindling wood not ignite? Condition, amount, arrangement of
kindling and fuel
Use more, drier, well-spaced kindling
and fuel.
Does the kindling ignite, but the fuel
doesn’t?
Amount of kindling
Condition of fuel
• Use more kindling
Use smaller, dry wood
Does the fuel ignite, but not burn well? Draft problem
Condition of fuel
Use well-seasoned wood and suf-
cient amount
Turn exhaust fans off
• Open window slightly
1. If I can’t get a good re going, what am I doing wrong?
2. I smell smoke in the house after we have had a re. What is the cause/what can I do?
Diagnostic Question Possible Causes of Condition Solutions
Is the chimney clean? No: Creosote odor Have chimney cleaned
3. I smell smoke in the house during operation. What is causing it?
Diagnostic Question Possible Causes of Condition Solutions
Do res start and burn well? No:
• Chimney obstruction
Not enough kindling and/or fuel to
establish draft
Inadequate combustion air
Air controls not open
Yes:
Competition with exhaust devices
No:
Check & clean chimney if needed
Use adequate kindling & fuel
Open air controls
• Open window
Check for need for balanced air
make-up (Outside Air)
Check door rope for seal.
Yes:
Do not use exhaust fans during
startup
Check for need for balanced air
make-up (Outside Air)
C. Diagnostics and Problem Solving