Pitco Frialator L80-029 Burner User Manual


 
L80-029 Rev 5 10/07 4
i. Capture the remaining burners on the SCBS Arm in
the same manner as in step h, and secure them into
the appliance, taking care not to strip the pre-threaded
holes.
j. Secure the SCBS Arm to left side of the burner to the
right of the pilot using two 10 X 24 self-threading
screws provided with the Pitco Self-Cleaning Burner
System Upgrade Kit.
The SCBS Arm should now be mounted properly and securely.
Inspect your work to insure that the burners are installed correctly.
Improperly mounted or poorly aligned burners may result in an
unsafe condition or poor appliance performance. They should be
mounted properly on the orifice fittings, facing straight into the
burner tubes and secured tightly to the appliance.
Follow this procedure for installation of the SCBS Valve:
NOTE: The valve type you receive in your kit may differ in appearance slightly from the one shown in these
instructions.
a. Re-attach the gas valve to the manifold inlet using a 1
1/16” wrench and a 15/16” wrench and, with a 3/16” (5
mm) hex key, remove the plug from the pressure tap
port on the TOP portion (Outlet Side) of the valve,
next to the pilot fitting.