Pitco Frialator L22-306 Water Heater User Manual


 
Solstice I12 Water Cooker Computer Service
Part #60153301
L22-306 Rev 0 19
5 Factory Menu Level 4 (for the Technician)
With no cook timers running, displays will show one of the following: [HEATING or [READY]. Press
the program key. Left display will show [PROGRAM]. Right display will be blank.
Enter password
Factory Password
using the location keys as numeric keypad for entry.
Display will show . The key indicators will illuminate to prompt
operator to select a key. This section details parameters that may be changed in Factory
programming.
5.1 Offset Temperature Display
This adjustment allows the displayed temperature value to be offset to reflect the true center vat
temperature while reading the probe tip temperature. Default value is zero. With zero value set,
displayed values are the probe temperature.
With display showing [FACTORY], press product key 1.
Display shows [OFF nn F] [DEGREES], where “nn” is the value of the adjustment.
Negative values are preceded with a minus sign. To change this value, use the location
keys for numeric entry of a new value.
Press the key. Display will show [POSITIVE] [DEGREES]. Use the product key to scroll
choices (Positive or Negative value). After selection, press the key. Display shows
[FACTORY].
Note: Computer Display Temp Center Vat Temp = Offset (+/-). Example: Computer Display shows
185F while Center Vat Temp measures at 182F; 185F – 182F = - 3 °F. A negative offset value.
Warning: Proper equipment and expertise is required to properly adjust this value. Even small changes
may negatively effect cooking performance.
5.2 Minimum Cycle Time
With display showing [FACTORY], press product key 3.
Display shows [MIN ON :nn] [MIN ON], where “nn” is the value, in seconds, of time for
minimum heat pulse period. To change this value, use the location keys for numeric entry of
a new value. Press the key. Display now shows [FACTORY].
5.3 Recovery Time
With display showing [FACTORY], press product key 4.
Display shows [RECY nnn] [RECOVERY], where nnn is the last cold start recovery time.
No adjustments are permitted here. This is an information display only. Press the