Pitco Frialator L22-306 Water Heater User Manual


 
Solstice I12 Water Cooker Computer Service
Part #60153301
L22-306 Rev 018
4.7.9 Standing Pilot Toggle
For some applications, it is desirable to maintain the gas pilot flame when the appliance is
OFF. Heat from the pilot keeps the vat warmer for quicker start-ups in the morning. Default
setting for standing pilot is off.
Note: Heat Demand Profile (section 4.8.3) must be set to Generic 1, or T-stat.
Standing Pilot toggle has no effect in any other setting.
With display showing [MORE] [SERVICE], press key . Display will show [STANDING]
[PILOT n], where “n” is ON or OFF. Use key to toggle value, then press the to
save choice. Display returns to [MORE] [SERVICE].
4.7.10 To Exit More Service Menu
With display showing [MORE] [SERVICE], press the key. Display returns to [SERVICE].
Continue with Level 2 programming in section 4 (display showing [SERVICE]), or continue.
4.8 To Exit Programming Level 3
With display showing [SERVICE], press the key. Display will show [PROGRAM]. Continue
with changes in section 2, or continue.
To return to normal operations, press the key again. Display will show one of the normal
displays: [HEATING] or [READY].