16. Improper stove ground.
Remedy: Check the ground. Check the outlet. Just because there is a three-prong outlet
receptacle does not mean that there is a ground wire hooked up to it, and then where does
that ground wire go to? This appliance must be properly grounded. Also remember that the
primary control grounds itself to the junction box, so never work on the unit with the
primary control off the junction box with the power on.
17. Loose wiring connection.
Remedy: Check power location with tester. Trace power in to control function. Look for
loose wires, wire nuts, terminals, and tighten. Make sure that the power is off when looking
for loose wires.
18. Defective thermostat.
Remedy: Remove the thermostat from the wall, cross the two wires, if this activates the
burner then replace the thermostat.
19. Break in thermostat wire.
Remedy: Go back to the wiring connection at the furnace where the thermostat wires tie in
to the yellow primary control wires, disconnect the thermostat wires, cross the yellow leads
off the primary control for the thermostat, if this activates the burner then either find the
break in the thermostat wire line or replace the entire line.
20. Draft rheostat on primary control set too low.
Remedy: Switch draft setting to next highest setting.
21. Draft rheostat on primary control set too high.
Remedy: Switch draft setting to next lowest setting.
22. Defective blower motor.
Remedy: Depress white button on fan limit control to check blower activation. If not
activated, pullout white button and connect power directly to blower leads, if not activated
by direct power then remove and replace blower.
23. Loose coupling on cup drive assembly.
Remedy: Tighten set screw down onto flat part of shafts with allen wrench. Remember that
the motor can be turning and everything looks like it is moving, but actually the couplings
are just turning, not the shaft or the cup.
24. Loose coupling on auger drive assembly.
Remedy: Tighten set screw down onto flat part of shafts with allen wrench. See second
comment above to note.
25. Burner limit 200-degree manual reset popped.
Remedy: Depress red button in between cup and auger motor. Verify correct operation of
the cup, auger, and draft inducer motors. Possible motor failure evident.
26. No voltage to stove.
Remedy: Check power backward, j-box, power cord, outlet, circuit breaker, etc. Also check
3 amp fuse in primary control.
27. Too many appliances on the circuit.
Remedy: The unit should be on a separate circuit.
23