TURNING OFF THE UNIT
Turn the power switch to draft fan. Fuel will stop feeding but the draft fan will remain
running. Let run until fire burns out completely. Set power switch to off.
NOTE: Approximately 10 – 12 minutes should be enough time for fire to burn out. Time will
vary depending on fuel type.
MAINTENANCE
1. Check the ash pan regularly and empty as necessary. Dispose of the ashes in a metal
container, and when cooled, bury them to prevent any spontaneous fires.
2. Check the fire pot regularly for any residue build-up. Clean and dispose of them when
completely cooled.
3. Remove the two heat exchanger access panels twice per burning season and check the
heat exchanger for ash. Vacuum if necessary. Replace gasket material if any tearing or
deterioration occurs.
4. Annually check the blowers for lint deposits from carpeting, dryer lint, furniture
coverings, pet hair, etc.
5. Inspect the flue pipe or vent assembly and chimney each time the heat exchanger is
serviced (minimum twice per heating season). Clean these passages as needed. Higher
usage of the unit could require more frequent cleanings.
6. Your unit is equipped with an aluminium air filter, wash and clean it regularly. At least
once a month
.
11