11. Let the pot cool completely to the touch and place into a bucket of water to dissolve
the clinker. DO NOT PLACE HOT POT IN WATER;
FAN LIMIT CONTROL
NOTE! INCORRECTLY INSTALLED
CONTROL CAN CAUSE ELECTRIC
SHOCK HAZARD OR DAMAGE TO
LOW VOLTAGE CONTROLS. ON ALL
GBU070 TRAGER MODELS THE BRASS
JUMPER MUST BE REMOVED.
BD 01/19/02 REV 2
GBU070 FURNACE WIRING
2 WIRE LOW VOLTAGE
THERMOSTAT
YELLOW
YELLOW
CUP MOTOR
AUGER MOTOR
DRAFT FAN
MANUAL RESET
WHITE
ORANGE
WHITE
BLACK
ORANGE
BLOWER 1/4 HP
DIRECT DRIVE
SAFETY DISC
RED
WHITE
YELLOW
RED
ORANGE
WHITE
GREEN
BLUE
BLACK
YELLOW
L1
L2
GND
110 VOLTS
A.C.
RED
BLUE
YELLOW
PURPLE
GREEN
13