ISACC INPUT SPECIFICATIONS
Voltage Range: 0 to +5 VDC
Minimum/Maximum Input Voltage: -0.5VDC to +5.5VDC
Input Resolution: 10 Bit or 0.004888V
A/D Converter Typical Total Unadjusted Error: ±1 LSB
Accuracy (TEMP POSITION): ±1° F typical using Phonetics 2.8K
temperature sensor
Accuracy (4-20mA POSITION): ±1.25%
Maximum Pulse Frequency: 1.0Hz
Minumum Pulse Width: 400ms
Noise Filtering: 2300Hz low pass filter
-20dB/Decade
INPUT MODULE SPECIFICATIONS
AC INPUT MODULE (FGD-0018):
Input Voltage: 90 - 140 VAC/VDC
Input Current: 8 - 12 mA
Output Current: 100 mA DC max.
Output Leakage: 100 µA DC max.
Logic Supply Voltage: 5 VDC
Logic Supply Current: 10 mA DC typical
DC INPUT MODULE (FGD-0017):
Input Voltage: 3-32 VDC
Input Current: 10-15 mA
Output Current: 100 mA DC
Output Leakage: 100 µA DC
Logic Supply: 5 VDC
Logic Supply Current: 10 mA DC