Philips CS-E15DB4EW Air Conditioner User Manual


 
D. Deodorizing Control
i. Control condition
Control at cooling/dry operation and auto fan speed.
No Deodorizing Control is performed during ON timer standby operation and during Anti-freezing control prevention.
ii. Operation
The odor status is arranged as below and it is shifted as follow.
* When COMP is ON 1
2
3
(Shift to 4 when COMP is OFF)
* When COMP is OFF 4
5
6
7
6
←→
7
(Shift to 1 when COMP is ON)
* Start from 4 if the Thermostat is OFF during the start operation.
Odor Status 1 2 3 4 5 6 7 6.7.6... 1
Status Shift
according to COMP
ON OFF ON
Status Shift
according
Cooling
zone
40 50 30 90 20 90 20.90.20...
to time (s) Dry zone ON
Fan Speed
Cooling
zone
OFF SSLo
Auto Fan Speed
SSLo OFF SSLo OFF SSLo.OFF...
Dry zone SLo
8.1.7. Outdoor Fan Motor Operation
Outdoor fan motor is operated with 15 fan speed. It starts when compressor starts operation and it stops 30 seconds after
compressor stops operation for speed no.8.
No. RPM during Fan Speed (rpm)
E21D E18D E15D
15 75 73 71
14 75 73 71
13 70 68 66
12 68 66 64
11 64 62 60
10 62 60 60
9 58 58 58
8 50 50 50
7 45 45 45
6 40 40 40
5 35 35 35
4 30 30 30
3 25 25 25
2 20 20 20
1 15 15 15
23
CS-E15DB4EW CU-E15DBE / CS-E18DB4EW CU-E18DBE / CS-E21DB4ES CU-E21DBE