![](http://pdfasset.owneriq.net/d/d2/dd2ff4a9-fc5f-4228-9a66-c0bed5cfbcbe/dd2ff4a9-fc5f-4228-9a66-c0bed5cfbcbe-bg37.png)
Adjustment
11 - 15
11. 04.13 Needle thread tension release
Requirement
With the presser foot raised, both of the tension discs must be at least 0.5 mm apart.
The clearance of 0.5 mm is a minimum and can increase to more than 1 mm
when using thick threads.
● Align pressure plate 1 behind tension carrier plate 2 in accordance with the requirement.
If the tension is correct, release pin 3 must not be under pressure.
Fig. 11 - 13
0.5 mm
3
2
1