Pella 801U0103 Window User Manual


 
4
SECURING THE WINDOW
A. Install a #10 x 3-1/2" corrosion
resistant wood screw into each pre-
drilled screw hole.
Note: Minimum 1-1/4" embedment
into the wall framing is required.
Proceed to Step 6.
ŘALL WINDOWS Ř ALL WINDOWS Ř
5
INSTALLATION CLIP METHOD
A. Fasten the window to the opening by driving two
#6 x 1-1/2" or longer corrosion resistant screws into
the pre-punched holes in the clips. If clips are bent and
fastened to the interior stud/block, install the screws as
close to the bend as possible.
Note: DO NOT shim above the window.
INTERIOR
6A
5A
#10 x 3-1/2"
corrosion
resistant
wood screw
4A
5A
Caution: Ensure use of low pressure polyurethane window and door insulating
foams and strictly follow the foam manufacturer’s recommendations for
application. Use of high pressure foams or improper application of the foam may
cause the window frame to bow and hinder operation.
6
INTERIOR SEAL
{
6A
A. Apply insulating foam sealant. From the interior, insert
the nozzle of the applicator into the space between the
window and the rough opening approximately 1" past
the edge of the frame (and past the jamb extensions)
and apply a 1" deep bead of foam. This will allow room
for expansion of the foam and will minimize squeeze
out. Apply sealant across the interior surface of the
shims to create a continuous seal. Follow foam
manufacturer's instructions.
Note: DO NOT place any foam between jamb
extensions and the rough opening.
Note: DO NOT completely fill the space from the
back of the fin to the interior face of the opening.
ŘPERFORMANCE UPGRADE & HURRICANESHIELD WINDOWS Ř