Pelco PT180-24SL Home Security System User Manual


 
6 Pelco Manual C314M-D (8/98)
Table B. Recommended Cable Distances Using RB24 Relay Box
Wire Maximum Maximun
Size Distance (feet) Distance (feet)
(Awg) “A” “B”
20 5,800 (1,768 m) 65 (19.81 m)
18 8,250 (2,515 m) 100 (30.48 m)
16 13,000 (3,962 m) 160 (48.77 m)
REQUIRES EXTERNAL
POWER SUPPLY
Maximum Distance
6 Conductors 7 Conductors*
20 AWG 65 ft (19.81 m) 85 ft (25.91 m)
18 AWG 100 ft (30.48 m) 135 ft (41.15 m)
16 AWG 160 ft (48.77 m) 220 ft (67.06 m)
Table A. Maximum Cable Distances to Wire Pan and Tilt Motors
A
B
RB24
MPT24DT/
MPTA24DT/
MPTAZ24DT
*Using 2-wire motor common
Cable distances are for both motors running and assuming a 10% voltage drop in
the cable.
Six-conductor cable, single common conductor is recommended. Distances are
approximate maximum recommended under the following conditions:
Simultaneous pan/tilt activation
Minimum 21.6 volts at pan/tilt
Operating distance may be extended by using an RB24 remote relay box. Refer to