Specifications
ELECTRICAL
Input Voltage 120 VAC (230 VAC optional) for heaters
Power Requirements 80 W
Connector 16-pin jam nut receptacle
Maximum Cable Distances
120 VAC
16 AWG (1.5 mm
2
) 2,238 ft (682 m)
18 AWG (1.0 mm
2
) 1,410 ft (430 m)
20 AWG (0.5 mm
2
) 1,040 ft (316 m)
230 VAC
16 AWG (1.5 mm
2
) 8,224 ft (2,507 m)
18 AWG (1.0 mm
2
) 5,182 ft (1,579 m)
20 AWG (0.5 mm
2
) 3,257 ft (993 m)
Heater 2 at 40 W, 120 VAC
NOTE: Heaters are thermostatically controlled to turn on at 40°F (4°C) and turn off at 60°F (16°C)
GENERAL
Construction Aluminum 6061 T6
Finish
Outside Gray polyester powder coat
Inside Black anodized
Front Window 6-inch diameter tempered glass, 0.225-inch thick
Camera Mounting Multiple mounting holes on camera sled allow for linear adjustment
Maximum Camera/Lens Size 5.0" D x 18.0" L (13 x 46 cm) or
18.0" L x 4.0" W x 4.0" H (46 x 10 x 10 cm)
Enclosure Mounting RediLINK 26-pin connector mates enclosure to pan/tilt
Purge Fitting Standard Schrader valve to allow enclosure to be filled with dry nitrogen
Purge Relief Fitting Prevents overpressurization of enclosure
Weight 17.2 lb (7.8 kg)
Ratings Meets NEMA Type 6 and IP 67 standards