Pelco C3422M-B Home Security System User Manual


 
12 C3422M-B (3/08)
Switch Settings
WARNING: If you are using Pelco D or Pelco P protocol control, your system may not operate if the baud rate and
address switches are not set correctly. The switches are set at the factory at the defaults for Pelco D protocol
control (2400 baud and address 1).
Table F. Switch Settings for SW2
Special Systems
Switch Number 12345678910
AD-32 Preset System ON
CM9502 Setting ON
Vicon Not currently available; SW2-3 is reserved for future use.
Serial Port Settings
Switch Number 12345678910
RS422 OFF OFF
RS485, 4-Wire OFF ON
RS485, 2-Wire ON ON
Pelco D and Pelco P Protocol Baud Rate
Switch Number 12345678910
2400 Baud (Default for Pelco D Protocol Control) OFF OFF OFF
4800 Baud (Default for Pelco P Protocol Control) ON OFF OFF
9600 Baud OFF ON OFF
Video Cable Type
Switch Number 12345678910
Coax Cable OFF
UTP Cable ON
Dome Termination
Switch Number 12345678910
Terminated ON
Not Terminated OFF