Pelco C1901M (4/99) Carbon Monoxide Alarm User Manual


 
Pelco Manual C1901M (4/99) 9
G
Connecting the Monitor to the MC3800 Series Cameras
F
Connecting the MC3800-2
123
1
2
CAMERA
Install the camera where it will not be affected by fluorescent lights or window reflections.
If the camera is used under illumination that is not steady, the picture may flicker.
The MC3800-2 must be operated with a 24 VAC, 60 Hz, Class 2 power supply.
The MC3800-2X must be operated with a 24 VAC, 50 Hz power supply.
The MC3800-3 must be operated with a 220-240 VAC, 50 Hz, power supply.
To connect the camera:
1. Refer to Illustration G. Connect the video cable (2) from the monitor to the VIDEO
OUT connector (1) on the camera.
2. MC3800-2/MC3800-2X: Connect the power leads to the camera. Refer to Illustration F.
a. Remove the insulation from the power cable wires.
b. Attach the terminal tips.
c. Connect the wires to the terminals on the camera.
d. Ground the unit or an irregular voltage may be generated in the AC power cord
and may cause malfunction or damage to the video camera. Ground the camera
at the screw labeled “G.”
Maximum cable lengths for 24 VAC: 18 AWG, 200 ft (60 m); 16 AWG, 325 ft (100 m).
3. Refer to Illustration G. Connect the power cord or leads (3) to a power source (4). For
the MC3800-3, the brown wire is the hot lead, the blue wire is neutral, and the green
and yellow wire is ground.
CC3300-2
CC3300-3
4
3
1 2
MC3800-2
MC3800-2X
MC3800-3